Yes : ✔ No : ✖ Good : ●●● Fair : ●● Poor : ● |
| GENERAL CONDITION |
| S.O.S. (All Compartments) | ✖ |
| GENERAL APPEARANCE |
| Cleaning Required | ✔ |
| SAFETY ITEMS |
| ROPS Certification Plate | ✔ |
| Safety Decals In Place | ✔ |
| Safety Decals Legible | ✔ |
| OPERATOR STATION |
| Current O&MM | ✖ |
| Current Parts Manual | ✖ |
| Current Safety Manual | ✖ |
| ENGINE |
| Blow By | ✖ |
| Fuel Leaks | ✖ |
| Knocking | ✖ |
| Oil Leaks | ✖ |
| Water in Oil | ✖ |
| COOLING SYSTEM |
| Compression in Radiator | ✖ |
| Folded Core Radiator | ✖ |
| Modular Radiator | ✔ |
| Standard Radiator | ✖ |
| ELECTRICAL, STARTING AND CHARGING SYSTEM |
| Block Heater | ✖ |
| Ether Aid | ✔ |
| TRANSMISSION |
| Leaks - TRANSMISSION | ✖ |
| Transmission - Noisy | ✖ |
| STEERING |
| Steering Linkage | ●●● |
| Steering Operating Condition | ●●● |
| HYDRAULICS |
| Leaks - HYDRAULICS | ✔ |
| BLADE |
| Cutting Edge & Bits | ●● |
| Face / Moldboard | ●● |
| Knuckle | ● |
| Pins | ●● |
| Spill Rack | ●● |
| Tower | ●●● |
| UNDERCARRIAGE |
| Leaks - HYDRAULICS | P&B have a 1/8”+ of movement |
| Leaks - HYDRAULICS | ✖n cat links used cat specs |
| Leaks - HYDRAULICS | Both pivot shaft seals are leaking |
| FINAL DRIVES |
| Housings, Left | ●●● |
| Housings, Right | ●●● |
| Planetaries / Differential, Left | ●●● |
| Planetaries / Differential, Right | ●●● |